15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type

Product Details
Customization: Available
Application: Power, Lighting
Phase: Three
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
103
Year of Establishment
2014-05-30
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
  • 15kv Pole Mounted Distribution Transformer 300kVA Oil Immersed Type
Find Similar Products

Basic Info.

Model NO.
S-300/15-0.4
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC, CE
Usage
Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EI
Brand
Rooq
Voltage Ratio
15/0.4kv
Frequency
50/60Hz
Vector Group
Dyn11/Yyn0/Dyn5
Cooling Type
Onan
Tapping
5 Steps
Transport Package
Wooden Case
Specification
725*540*820mm
Trademark
ROOQ
Origin
China
HS Code
850422
Production Capacity
500PCS/Month

Product Description

Summary
Transformers immersed in insulating fluid with natural self cooling (ONAN), three-phase, 50/60 Hz.
For indoor or outdoor use.
Hermetically sealed, CRGO Silicon steel, High-strength cold-rolled steel tank.

Standard
The transformers described in this catalogue are designed and tested in accordance to IEC/BSEN 60076.

Features
Common power ratings:
30, 50, 80,100,125,160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500 kVA.

This transformer is designed for voltages of ≤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltages used. Transformers can be supplied on demand to run at two different primary voltages, the shift between these input voltages has two
basic alternatives:
• with a primary tap changer which can be switched with no load and no applied voltage
• or by changing terminals under the cover.

The secondary voltage under no load is allocated at 400V, 415V, 433V, though other voltages can be supplied on demand.

When usage requires two voltages, transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 400V(230V),415V(240V),433V(230V) .

The connections normally used are as follows:
• For rated power levels of 160 kVA or less: Yyn0
• For rated power levels over 160 kVA: Dyn11.
• Dyn5, Yd11 and others can customaized.

As per IEC /BSEN 60076 standards these are
set in accordance with the highest voltage for the material,
being the level immediately above the rated voltage.
Material maximum admissible voltage 12kV 17,5kV 24kV 36kV
Withstand voltage 28kV 38kV 50kV 70kV
Basic insulation level 75kV 95kV 125kV 170kV

As per IEC/BSEN 60076 , in normal operating mode:
• 60º K max. in oil
• 65º K average in windings
Other temperature rise levels on demand.

Transformers covered must have one of the following oil expansion systems:
a) an external conservator tank
b) an air chamber under the cover
c) a hermetically sealed elastic tank
ROOQ recommends option (c), which is the one considered in this catalogue, as it has the following advantages:
1.Smaller size, as there is no need for an conservator tank or air chamber, making for easier transformer transportation and placement.
2.Lower overall weight.
3.Increased sturdiness and less risk of leaks, there being no weak points such as welds between the expansion tank    and the cover, oil level gauge, Silicagel air breather, etc.
4.Low maintenance due to the absence of elements such as the drier, over-pressure valves and liquid level indicators.
5.No degradation of insulating liquid (oil) by oxidation or absorption of moisture, as there is no contact with the air. The liquid therefore remains in ideal condition.
6.Better conservation of seals due to lack of contact with air, which means that they stay more flexible.

Construction details
I- MAGNETIC CIRCUIT
Oriented grain, very low loss magnetic plate is used following IEC/BSEN 60076. The type or class of plate is chosen on the basis guaranteed noise level and losses. The net cross section is maintained constant in limbs and yokes throughout the magnetic circuit, as a special configuration does away with the need for cross-section reducing grip bolts (section reduction).

The limbs and yokes are joined by 45º lugless joints, with complete one-piece yoke, and stacking is arranged so that each plate profile is staggered with regard to the previous one, thus minimising the effect of the gap. The profile is stepped, with the number of steps required to obtain the best coefficient of useful surface area.

II- LOW VOLTAGE WINDING
This winding is located next to and concentric with the magnetic circuit. Two clearly different types of wire are used depending on the allocated current:

- Rectangular cross-section with rounded edges. 
- Strips with conditioned edges.
In the former case each wire is insulated with thermal class A cellulose paper or class H enamel. Strips are used bare.

The rectangular wire winding is set up in a complete layer configuration with one or more concentric channels for cooling.

The insulation between layers is always B status resin impregnated.

The width of the strip on strip type winding with conditioned edges covers the whole axial width of the coil, so that each turn is a layer of winding. As the strip is wound a layer of type B resin impregnated paper is wound with it. This polymerises during the drying cycle, giving the winding the strength to withstand the mechanical stresses entailed by short circuits as per IEC 60076 standards.

III- HIGH VOLTAGE WINDING
This is wrapped around the low voltage winding to lie concentric with it, separated by an insulation structure giving the level of insulation desired.

The conductors used are of two types:

• circular cross-section wire
• rectangular cross section strips.

The conductors are insulated with thermal class H enamel. The rectangular section wires or strips have thermal class A paper or thermal class H enamel. With both types of wire, the winding configuration is anti-resonant in one section, making it highly resistant to ray type pulse waves.

The insulation between layers is resin impregnated, polymerising during drying to give the winding the strength to withstand the mechanical stresses entailed by short circuits.

IV- ACTIVE PART
This is the name given to the set of elements which can be removed from the tank of the transformer. Apart from the core and windings,the main elements are:

• fixing and guide structure
• tap changer
• cover
• cover bushing

V- TANK
The distribution transformer tank is elastic, enabling it to absorb the increase in volume of insulating fluid as it heats up due to the transformer operation without experiment permanent deformations. It comprises the following components:

• supporting frames
• base
• cooling fins
• outer frame

- The supporting frames are welded to the base in a continuous, watertight bead to prevent rusting. They have holes for attaching wheel heads and dragging the transformer.

- The base is bath shaped, with earth connections and a drainage device on the sides.

- The cooling fins are the fundamental part of the tank: they form the corrugated side walls and give it the required elasticity.They are made of cold-rolled steel plate between 1 and 5 mm thick, bent without drawing. Elasticity is obtained by a suitable combination of height, depth, plate thickness and resulting internal pressure.

- The outer frame of the tank is made of L-section steel, welded to the top of the corrugated side walls. The top of this frame houses the pressure limiters for the seal and bear the holes for the cover/tank fixing screws.

The two tables below indicate the guaranteed rated figures as per IEC60076 standards.
These figures are valid for a single secondary voltage, even if there is more than one primary voltage.



Highest voltage for material: 12 kV
 
Rated capacity (kVA) H.V.  
 (kV)
Tapping range L.V.  (kV) Vector group Loss(kW) No-load current (%) Impedance voltage  (%) Weight (kg)
Load loss No-load loss oil Total
10 6        10      11      ±5%             or     ±2*2.5% 0.4   0.415 0.433 Dyn11          or            Yyn0 0.26 0.09 3.2 4 45 172
20 0.44 0.10 3.0 65 240
30 0.63 0.13 2.3 65 245
50 0.91 0.17 2.0 80 330
63 1.09 0.20 1.9 90 365
80 1.31 0.25 1.9 95 410
100 1.58 0.29 1.8 115 490
125 1.89 0.34 1.7 140 620
160 2.31 0.40 1.6 155 720
200 2.73 0.48 1.5 175 810
250 3.20 0.56 1.4 200 940
315 3.85 0.67 1.4 215 1090
400 4.52 0.80 1.3 240 1250
500 5.41 0.96 1.2 285 1460
630 6.20 1.20 1.1 4.5 345 1720
800 7.50 1.40 1.1 390 2050
1000 10.30 1.70 1.0 460 2430
1250 12.00 1.95 1.0 550 2850
1600 14.50 2.40 0.8 690 3600
2000 18.00 2.60 0.7 790 4300

Highest voltage for material: 15-24 kV
 
Rated capacity(kVA) H.V. (kV) Tapping range L.V. (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weight (kg)
Load loss No-load loss oil Total
30 15        20 ±5%               or          ±2*2.5% 0.4  0.415 0.433 Dyn11         or           Yyn0 0.60 0.10 2.1 4 85 350
50 0.87 0.13 2.0 90 480
63 1.04 0.15 1.9 110 600
80 1.25 0.18 1.8 110 660
100 1.50 0.20 1.6 120 700
125 1.80 0.24 1.5 130 800
160 2.20 0.29 1.4 140 940
200 2.60 0.33 1.2 160 1130
250 3.05 0.40 1.2 180 1290
315 3.65 0.48 1.1 230 1400
400 4.30 0.57 1.0 250 1550
500 5.15 0.68 1.0 260 1780
630 6.20 0.81 0.9 4.5 320 2100
800 7.50 0.98 0.8 350 2560
1000 10.30 1.15 0.7 450 2800
1250 12.00 1.36 0.6 490 3200
1600 14.50 1.64 0.6 640 4000
2000 17.14 1.94 0.6 800 4900
2500 20.26 2.30 0.5 1180 6300

Highest voltage for material: 36 kV
 
Rated capacity(kVA) H.V.  (kV) Tapping range L.V.  (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weightb (kg)
Load loss No-load loss oil Total
50 30        33       35    38.5 ±5%                or          ±2*2.5% 0.4   0.415 0.433 Dyn11    Yyn0      Yd11 1.27 0.21 2.0 6.5 265 860
100 2.12 0.29 1.8 310 1150
125 2.50 0.34 1.7 320 1190
160 2.97 0.36 1.6 360 1230
200 3.50 0.43 1.5 390 1300
250 4.16 0.51 1.4 425 1480
315 5.01 0.61 1.4 460 1590
400 6.05 0.73 1.3 490 1760
500 7.28 0.86 1.2 540 2150
630 8.28 1.04 1.1 620 2380
800 9.90 1.23 1.0 780 2800
1000 12.15 1.44 1.0 850 3410
1250 14.67 1.76 0.9 950 3890
1600 17.55 2.12 0.8 1060 4620
2000 19.35 2.72 0.7 1195 5345
2500 20.70 3.20 0.6 1285 5960
3150 24.30 3.80 0.6 7 1470 6695
4000 28.80 4.52 0.5 1760 8350

Pictures