Product Introduction
VS1 indoor medium voltage Vacuum Circuit Breaker:
VS1 indoor medium voltage Vacuum Circuit Breaker is a
three-phase AC 50Hz ,rated voltage 6KV,12KV,24KV switch
equipment of power system.
Breaker adopts the integral design of the actuating
mechanism and the breaker body, which can be used as a
fixed installation unit or as an individual VCB carriage
together with handcart. They have a long life expectancy.
There is no adverse effect on the vacuum, even from
frequent switching of operating and short-circuit currents.
Product Advantage
1.Reliable Structure
VS1 type VCB consist of operating mechanism and arc-extinguish chambers in front-back arrangement, its main conductive circuit is floor model structure. The vacuum arc-extinguish chamber is fixed in a vertical cannular insulation column made of epoxy resin by APG technology, therefore with high anti-creepage function. Such structure design greatly reduces the accumulation of dusts on the surface of vacuum arc- extinguish chamber, it not only can prevent the vacuum extinguish chamber from outside influences, but also can ensure to present high resistance state against the voltage effect even in warm-wet climate or heavy pollution environment.
1.with reliable interlock functions, suitable for frequent operation;
2.low noise and energy consumed;
3.simple and robust construction;
4.high operating reliability;
5.mechanical durability of switch : 20000 times, etc
2. High-Quality
1. Our factory has a unique comprehensive testing center, and each finished transformer needs to pass the test before it can be shipped;
2. After each process in the production of the transformer is completed, we will conduct a qualified test, and the quality of the transformer has reached the highest level.
Mechanical Parameters
No. |
Item |
Unit |
Date |
1 |
Rated voltage |
KV |
12 |
24 |
2 |
Clearance between open contacts |
mm |
11±1 |
13±1 |
3 |
Over travel of moving contact |
3.5±0.5 |
3.5±0.5 |
4 |
Three poles asynchronous time at opening |
ms |
≤2 |
≤2 |
5 |
Moving contact bounce time at closing |
ms |
≤2 |
≤2 |
6 |
Average opening speed |
m/s |
0.9-1.2 |
0.9-1.2 |
7 |
Average closing speed |
0.6-0.8 |
0.6-0.8 |
8 |
Connecting pressure of close contacts |
N |
20kA |
25kA |
31.5kA |
40kA |
20kA |
25kA |
31.5kA |
40kA |
2000±200 |
2400±200 |
3100±200 |
4250±200 |
2000±200 |
2400±200 |
3100±200 |
4750±200 |
Main characteristics
No. |
Item |
Unit |
|
1 |
Rated voltage |
KV |
12 |
24 |
2 |
Power frequency withstand voltage |
42 |
65 |
3 |
Lightning impulse voltage(peak value) |
75 |
125 |
4 |
Frequency |
Hz |
50 |
50 |
5 |
Rated current |
A |
630 1250 |
630 1250 1600 2000 2500 3150 |
1250 1600 2000 2500 3150 4000 |
630 1250 |
630 1250 1600 2000 |
1600 200 2500 |
6 |
Short circuit breaking current |
kA |
20/25 |
31.5 |
40 |
25 |
25/31.5 |
31.5/40 |
7 |
Thermal stability current |
kA |
20/25 |
31.5 |
40 |
25 |
25/31.5 |
31.540 |
8 |
Dynamic stable current |
kA |
50/63 |
80 |
100 |
63 |
80 |
100 |
9 |
short-circuit making current |
kA |
50/63 |
80 |
100 |
63 |
80 |
100 |
10 |
Rated current breaking time |
Times |
20000 |
20000 |
11 |
Short circuit breaking current times |
Times |
≤50 |
≤30 |
12 |
Operation voltage |
V |
AC/DC 110/220 |
AC/DC 110/220 |
13 |
Input power |
W |
70 |
70 |
14 |
Storage time |
s |
≤15 |
≤15 |
15 |
3 phase non-synchronous |
ms |
≤2 |
≤2 |
Our Service
We have our own warehouses and repair points in some countries, and the after-sales service is more convenient and efficient.

Sufficient Trade Experience
Our company has been established for nearly 20 years. It is the first batch of electrical companies to enter the foreign trade industry, with customers all over the world.Therefore, we can solve any problems for you before, during and after sales with great experience.
About Us






FAQ
Honny, here are some common questions. If you have any other questions, please send me a message.