Product Introduction
VS1 indoor medium voltage Vacuum Circuit Breaker:
Rooq's ring main units (RMU) can be adapted to meet all Medium Voltage power distribution needs,up to 24 kV.
The RM6 is a compact unit combining all MV functional units to enable connection, supply and protection of transformers on an open ring or radial network:
1.by a fuse-switch combination, up to 2000 kVA
2.by a circuit breaker with protection unit, up to 8000 kVA.
The switchgear and busbars are enclosed in a gas-tight chamber, fi lled with SF6 and sealed for life.
Operating a distribution network sometimes requires switching oints in addition to the HV/MV substations, in order to limit the effect of a fault on the network.
The RM6 offers a choice of solutions to make 2, 3 or 4 directional connections:
1.with line protection by 630 A circuit breakers
2. with network switching by switch-disconnectors
3. with integrated power supply telecontrol devices.
Product Advantage
1.Reliable Structure
RM6 switchgear comprises 1 to 4 integrated, low dimension functional units. This self-contained, totally insulated unit comprises:
1. a stainless steel, gas-tight metal enclosure, sealed for life, which groups together the live parts, switch-disconnector, earthing switch, fuse switch or the circuit breaker.
2.one to four cable compartments with interfaces for connection to the network or to the transformer.
3.a low voltage cabinet
4.an electrical operating mechanism cabinet.
5.a fuse chamber compartment for fused switch- disconnectors or fuse switches.
The performance characteristics obtained by the RM6 meet the defi nition of a "sealed pressure system" laid down in the IEC ecommendations.
The switch-disconnector and the earthing switch offer the operator all necessary usage guarantees:
Tightness
The enclosure is filled with SF6 at a 0.2 bar gauge pressure. It is sealed for life after filling. Its tightness, which is systematically checked at the factory, gives the switchgear an expected lifetime of 30 years. No maintenance of live parts is necessary with the RM6 breaking.
Circuit breaker
Electrical arc extinction is obtained using the rotating arc technique plus SF6 auto-expansion, allowing breaking of all currents up to the short-circuit current. .
2. High-Quality
1. Our factory has a unique comprehensive testing center, and each finished transformer needs to pass the test before it can be shipped;
2. After each process in the production of the transformer is completed, we will conduct a qualified test, and the quality of the transformer has reached the highest level.
Mechanical Parameters
Rated voltage |
12kV |
17,5kV |
24kV |
Frequency |
50 or 60 Hz |
Insulation level |
|
Industrial frequency 50Hz 1 min. insulation Ud (kv rms) |
28 |
38 |
50 |
isolation Ud (kv rms) |
32 |
45 |
60 |
Impulse 1.2/50us insulation Ud (kv rms) |
75 |
95 |
125 |
isolation Ud (kv rms) |
85 |
110 |
145 |
Tank interal arc withstand |
20kA 1s |
Our Service
We have our own warehouses and repair points in some countries, and the after-sales service is more convenient and efficient.

Sufficient Trade Experience
Our company has been established for nearly 20 years. It is the first batch of electrical companies to enter the foreign trade industry, with customers all over the world.Therefore, we can solve any problems for you before, during and after sales with great experience.
About Us






FAQ
Honny, here are some common questions. If you have any other questions, please send me a message.