• 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
  • 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
  • 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
  • 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
  • 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
  • 33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer

33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer

Application: Power
Phase: Three
Core: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000, ISO9001
Customization:

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
S11-2000kVA/33kV
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
OD
Brand
Rooq
Certificate
CE, ISO
Transport Package
Wooden Case
Trademark
ROOQ
Origin
China
HS Code
8504210000
Production Capacity
5000mva One Year

Product Description

33kv 2000kVA Oil Immersed Three Phases Power Distribution TransformerOil immersed distribution transformer with conservator

This type of oil immersed distribution transformer is equipped with conservator which mounted above the main tank.
This is not hermetic type transformer, so the transformer oil is always in contact with the air. The main function of the transformer oil conservation is to prevent the transformer oil in the oil tank from contacting with the air, so as to avoid the oxidation and deterioration , water infiltration and reducing the insulation dissipation.. Due to the difficult sealing of large transformer, when the transformer oil expands with heat and shrinks with cold, there must be water in the oil tank. After installing the oil gasket, when the oil is heated and expanded, part of the oil will enter the conservator, and when the oil is cooled, part of the oil will return to the tank, so as to avoid large area contact between the insulating oil and the air and reduce oxidation and water infiltration.

When the volume of transformer oil expands or shrinks with the temperature of oil, the conservator plays the role of oil storage or oil replenishment to ensure that the oil tank is full of oil. At the same time, it also reduces the contact area between oil and air and reduces the deterioration speed of oil. Its side is also equipped with an oil standard tube (ferromagnetic oil level gauge) to monitor the oil level change. The volume of the transformer oil is about 1 / 10 of the volume of the transformer oil, which is based on the standard that it can be seen when the transformer is stopped in winter and does not overflow when the maximum load is in summer. The indicated value of the ferromagnetic oil level gauge shall correspond to the temperature oil level curve on the transformer body.

There are two types of conservator (conservator) of transformer: main body (oil tank) and tap changer (conservator). It is required that the oil level of the main body is slightly higher than the tapping oil level to prevent the oil of the tapping oil tank from infiltrating into the main body oil tank and affecting the insulation of the oil tank of the transformer main body. Because the oil in the tap tank has arc extinguishing effect, the oil deteriorates quickly and there are many impurities. The function of tap changer oil filter is to automatically filter oil once after each action and pressure regulation of on load tap changer.


Application
Power stations, switchgear, factory, agriculture, hospitals, buildings, airports, tunnels, chemical plants, nuclear power plants etc.

Service Environment
Device types: outdoor type
Normal environment conditions of use: the elevation not more than 1000 m
Environmental highest temperature + 40°C, minimum-25°C
The special environment conditions of use: elevation of more than 1000 m
Environmental highest temperature + 40°C, minimum-45°C. (when you order details)
Mounting ambicnt: no corrosive gas, no obvious dirt environment

33kV series three phase oil filled distribution transformer manufactured by Zhejiang ROOQ Electric Co.,Ltd.,is a kind of energy-saving oil filled distribution power  transformer classified as S9 / S11 /S13 series( with no-load tap changer,OCTC) and SZ9 /SZ11/SZ13 series (with on-load tap changer,OLTC) .


Type :  Oil filled distribution transformer  / Oil immersed distribution transformer /Liquid filled transformer
Rated Capacity: 2000kVA
Rated Voltage:
33kV/11kV   33kV/415V   33kV/6.6kV  33kV/380V
35kV/10kV   35kV/0.4
The rated voltage can be customized as customers' requirements.

Why choose ROOQ distribution transformer?
 
  1. Low loss, low noise, low partial discharge, low temperature rise and energy-saving
  2. Adopt the latest insulatoin structure
  3. Excellent anti-short-circuit ability.
  4. As to the heat dissipating element adopts corrugated sheet or sheet radiator and other components.
  5. The iron core adopts high quality cold rolled graind oriented silicon steel sheet ,it is low loss and small magnetostriction.The whole iron core adopts the structure of 45-degree full oblique joint and round cross-section, which will not be loosened due to vibration during transportation and operation.



Application
Power stations,compact transformer station, normal industrial factories , mines , hospitals, buildings, airports, tunnels, chemical plants, nuclear power plants etc.




33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer

Rated Capacity
(kVA)
Rated Voltage (KV) Short-Circuit Impedance
(%)
Connection Symbol No-load Losses(W) Load Losses
(W)
 No-load Current
(%)
Weight(kg) Outline Dimension
(L×W×H,mm)
High voltage (KV) High voltage tapping range Low voltage (KV) Oil Weight Body Weight Overall Weight
50 33
35
±5%,
     
              ±2×2.5%
0.4 6.5 Dyn11
/Yyn0
0.17 1.21/1.15 2.0 250 340 800 1090×940×1870
100 0.23 2.02/1.92 1.8 400 540 1150 1130×1140×1980
125 0.27 2.38/2.26 1.7 450 570 1300 1250×1270×2010
160 0.29 2.83/2.69 1.6 530 620 1555 1290×1300×2030
200 0.35 3.33/3.17 1.5 550 780 1650 1350×1320×1990
250 0.41 3.96/3.77 1.4 580 830 1720 1750×1150×2020
315 0.49 4.76/4.54 1.4 610 920 1850 1850×1210×2090
400 0.58 5.75/5.48 1.3 645 1015 2160 2060×1200×2260
500 0.69 6.92/6.59 1.2 750 1320 2620 2180×1250×2320
630 0.83 7.87 1.1 760 1550 2790 2200×1260×2430
800 0.98 9.41 1.0 980 1800 3800 2200×1350×2550
1000 1.15 11.55 1.0 1150 2300 4230 2450×1380×2580
1250 1.41 13.94 0.9 1230 2380 4480 2480×1600×2500
1600 1.70 16.68 0.8 1540 3050 5720 2650×1810×2850
800 33
35
10.5
6.3
3.15
6.5 Yd11 0.98 9.41 1.0 980 1800 3800 2220*1350*2550
1000 1.15 11.55 1.0 1150 2300 4230 2450*1380*2580
1250 1.41 13.94 0.9 1230 2380 4480 2480*1600*2500
1600 1.70 16.68 0.8 1400 2950 5540 2650*1810*2850
2000 2.18 18.39 0.7 1600 3150 6200 2700*1900*2880
2500 2.56 19.67 0.6 1780 3670 7100 2830*2370*2850
3150 33
35
38.5
10.5
6.3
3.15
7 3.04 23.09 0.56 1960 4930 8630 2905*2370*2960
4000 3.62 27.36 0.56 2200 5100 9430 2900*2680*3190
5000 4.32 31.38 0.48 3100 6300 11750 3000*2540*3200
6300 7.5 5.25 35.06 0.48 2930 6900 12200 3350*2720*3200
8000 33
35
38.6
11
10.5
6.6
6.3
7.5 Ynd11 7.20 38.48 0.42 3000 8650 14600 3580*3220*3400
10000 8.71 45.32 0.42 3750 9150 17050 3650*3400*3500
12500 8 10.08 53.87 0.4 4200 12300 20050 3850*3300*3750
16000 12.16 65.84 0.4 4800 14000 23900 3950*3000*3920
20000 14.40 79.52 0.4 5850 17850 30250 4150*3800*4200
 
Capacity
 (kVA)
Voltage Vector
group
Short-circuit impedance
%
Loss(KW) No-load current (%) Weight (Kgs) Dimension
High voltage (KV) High voltage tapping range Low voltage (KV) Load No-load Body Weight Oil Weight Overall Weight L*W*H
800 33kV
35KV
38.5KV
±5%,                     ±2×2.5% 0.4kV
3.15kV
6.3kV
10.5kV

Dyn11
Yd11
6.5 0.98 9.41 1 1763 995 3689 2290*1215*2530
1000 1.15 11.54 1 2125 1082 4260 2380*1240*2665
1250 1.41 13.94 0.9 2445 1250 4775 2620*1670*2680
1600 1.7 16.67 0.8 2985 1523 5788 2580*1760*2785
2000 2.18 18.38 0.7 3156 1687 6292 2630*1865*2811
2500 2.56 19.67 0.6 4250 1925 6480 2810*2150*2985
3150 7 3.04 23.09 0.56 4580 2100 8780 2770*2720*2750
4000 3.62 27.36 0.56 5340 2325 9970 2890*2840*2800
5000 4.32 31.38 0.48 6500 2640 11640 3665*2870*3070
6300 7.5 5.25 35.06 0.48 7870 2960 14000 3710*2870*3270
8000 YNd11 7.2 38.48 0.42 9650 3300 16100 3940*3280*3370
10000 8.7 45.32 0.42 1113 5395 19120 3880*3260*3480
12500 8 10.08 53.87 0.4 14600 4800 24300 4110*3360*4560
16000 12.16 65.84 0.4 16260 5800 27300 4450*3490*3840
20000 14.4 79.52 0.4 19000 6400 31300 4330*3550*3940
25000 17.02 94.05 0.32 22500 7350 36600 4660*3590*4340
31500 20.22 112.86 0.32 26700 8700 43200 4830*5100*3160



33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer33kv 2000kVA Oil Immersed Three Phases Power Distribution TransformerEstablished in September 2008, ROOQ  Electric Group Co.,Ltd is a technology-oriented enterprise specializing in R&D, production, sales and services of power transformers, HV/LV switch cabinets and related products.
  Since its inception, our company has been committed to the path of professional development. By virtue of its strong technical force, domestic and foreign advanced equipment, innovative ideas and extensive manufacturing experience, it has been certified by ISO9000 and adopts CAD to provide customers with environment-friendly, energy-saving, low-carbon and high-quality products suitable for regional characteristics to meet the market and the basic requirements of different customers. Now it has become one of the key enterprises in the Chinese manufacturing industry of key transformers and HV/LV switchgears.
  Currently the company mainly produces HV/LV power distribution cabinets, pre-fabricated substations, power distribution transformers, HV/LV switches and other products.
   Its products cover the national market of China. Also the products are exported to Central Asia, Africa, Southeast Asia, the Middle East, South America and other countries and regions.
  Based on its complete marketing and service networks,  ROOQ Electric Group Co., Ltd will further expand into the domestic and foreign markets. The company implements a "7*24 service mechanism" and an after-service policy with life-long warranty to actively provide its customers with timely, warm and total services, enhance the product utilization value and premium services and free its customers from any after-sales concerns.


33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer
33kv 2000kVA Oil Immersed Three Phases Power Distribution Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
103
Year of Establishment
2014-05-30