• 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
  • 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
  • 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
  • 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
  • 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
  • 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure

2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure

Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000, UL, ISO9001, CCC, CE
Customization:

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SCB10-2000KVA
Usage
Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
OD
Brand
Rooq
Altitude
1000m
Certificate
ISO ,CE
Service Condition
Indoor
Transport Package
Wooden Case
Specification
SCB10-400KVA/11KV
Trademark
ROOQ
Origin
Wenzhou/China
HS Code
8504349000
Production Capacity
5000mva One Year

Product Description

2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel EnclosureProduct Description
The SCB10 epoxy resin cast dry-type transformer produced by ROOQ ELECTRIC GROUP CO.,LTD. is made of high-quality materials and scientific formula, using advanced production testing equipment according to strict processes. The product has the characteristics of high reliability and long service life. According to different use environments, shells with different protection levels or no shells can be configured. Suitable for important or special environmental places such as high-rise buildings, commercial centers, airports, tunnels, chemical plants, nuclear power plants, ships, etc.

Product features:

  1. It is safe, fireproof and pollution-free.
  2. Adopting German HTT technology, it has high mechanical strength, strong short circuit resistance, small partial discharge, good thermal stability, high reliability and long service life.
  3. Low loss, low noise, excellent energy saving effect, maintenance free.
  4. It has good heat dissipation performance and strong overload capacity.
  5. Good moisture-proof performance, suitable for operation in high humidity and other harsh environment.
  6. It can be equipped with perfect temperature monitoring and protection system. The intelligent signal temperature control system can be used for automatic monitoring.
  7. The working temperature of three-phase winding can be displayed in circuit, and the fan can be started and stopped automatically, and alarm and trip functions can be set.
  8. Small size, light weight, less space occupied and low installation cost.

Ambient temperature:
  1. Max temperature +40ºC,Daily average max temperature +30ºC,Max yearly average temperature +20ºC.
2. The elevation should not be beyond 1000m.
3. The voltage waveform for the power supply is almost like sine wave and three-phase power supply voltage is approximately symmetric.
4. Special conditions of use
 Provided in the clients' inquiry sheet in detail (such as, high elevation and ambient temperature higher than 40ºC, etc.)

Cooling System
  1. The product generally adopts natural air cooling (AN) and it can continuously output 100% rated load. For the transformers of any protection grade, they can be equipped wind cooling system. If necessary, forced air cooling (AF) can be adopted to improve output power for emergent use in the case of dropping coil temperature or short-time overload.
  2. If the output load rate is more than 65% or the ambient temperature is very high, put it into the fan and cool the coil, which effectively decreases the coil's on-load loss and drops its hot-point temperature-rise in order to reach double function, that is, energy conserving and prolonging the coil's lifespan.
  3. It is advised that the fan is started via automatic control of thermostat. In default, the thermostat of the company sets the transformer to start the fan under 120ºC and 100ºC fan stopping, 140ºC alarm and 155ºC tripping, so the clients need not adjust in general.

4. For normal running, every 1 kW loss (Po+Pk) needs 4m3/min ventilation rate in general. When the transformer is installed in basement or other environments with worse ventilation ability, a heat dissipation and ventilator should be added to help air circulation.
Warning: If the transformer starts the wind cooling equipment and it is run beyond nameplate's capacity, check the transformer's actual loss under real running load to confirm whether the ventilation of the transformer room meets the requirement. If the ventilation is not enough, the transformer's heat dissipation might be difficult and the transformer will suffer serious influence.


2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure


Rated Capacity
(kVA)
Rated Voltage (KV) Vector Group Short-Circuit Impedance
(%)
Loss(kW)  No-load Current
(%)
Weight(kg) Outline Dimension
(L×W×H,mm)
Enclosure Dimension
(L×W×H,mm)
High voltage (KV) High voltage tapping range Low voltage (KV) No-load Losses Load Losses
30 6KV   6.3KV
6.6KV  10KV 11KV 13.8KV
 ±5%
 ±2× 2.5%
0.4  Dyn11
Yyn0
4 0.195 0.71 2.5 340 780×450×790 900×900×1080
50 0.275 0.95 2.2 430 840×450×855 1000×900×1150
80 0.375 1.385 2.1 560  900×600×885 1060×1000×1180  
100 0.405 1.58 1.9 720 920×600×900 1080×1000×1200
125 0.475 1.895 1.8 830 980×600×960 1140×1000×1260  
160 0.55 2.14 1.8 940  1040×710×1000 1240×1050×1300
200 0.63 2.54 1.6 1250 1070×710×1200 1270×1050×1450  
250 0.73 2.77 1.5 1450  1140×710×1245 1340×1050×1550
315 0.89 3.485 1.4 1600 1180×710×1300 1360×1050×1600
400 0.99 4.01 1.4 1980 1380×960×1425 1540×1150×1720
500 1.175 4.91 1.3 2300 1400×960×1515  1570×1150×1810
630 1.36 5.91 1.3 2570 1440×960×1595  1610×1150×1900
630 Dyn11
Yyn0
6 1.315 5.995 1.2 2550 1500×960×1405 1660×1150×1700
800 1.54 6.99 1.2 2810 1560×960×1575          1680×1150×1870
1000 1.79 8.17 1.1 3210  1640×960×1685 1750×1200×1980
1250 2.115 9.75 1.1 3400 1700×1255×1815 1850×1400×2120
1600 2.48 11.8 1 4150 1800×1255×1980 1920×1400×2280
2000 3.36 14.535 0.9 5600 940×1255×2110 2050×1450×2420
2500 4.05 17.27 0.8 6300 2060×1255×2350  2170×1450×2750
2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure

2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure
2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel Enclosure

 2000kVA Epoxy Cast Dry Type Transformer with Stainless Steel EnclosureQ1: How long is the Warranty for ROOQ products?
A1: ROOQ provides 24 months for the whole machine from on board time.

Q2: How about the delivery time?
A2: Usually producing time is 15- 20 days after we receive the advanced payment. For some standard products, like 10kV series oil immersed distribution transformer, we may have stock and could delivery immediately.

Q3: Can ROOQ provide customized products? OEM products or ODM products?
A3: Yes, ROOQ can provide customized products as per your request, both OEM and ODM are acceptable. We do a lots of non-standard products, welcome your special reqeust.

Q4: What's the payment term?
A4: We can accept T/T or L/C.


Q5: Could you offer Form A , Form E, C/O or other original documents ?
A5: Yes, of course,  just tell us your requests when you place the order.


Any inquiries, be free to contact me !!!

+86 183 5777 6757

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
103
Year of Establishment
2014-05-30